跳至主要内容

Countstar® Rigel S6 Advanced Image Cytometer

Countstar® Rigel S6
Advanced Image Cytometer





  • PBMC cell count and Primary Cell Count
  • Cell Apoptosis
  • Cell Cycle
  • Surface Marker Analysis
  • GFP Transfection Efficiency
  • Optional FCS Express Software

Product Overview
Countstar® Rigel S6 is an automated image-based cell analysis platform with full-spectrum fluorescence Microscope, FCS Express software, analysis and reporting of both data and image.

Countstar® Rigel S6 equipped with 4 fluorescence channel, allow for 13 different fluorescent analysis combinations, support any dye of different wavelength.

Excitation light: 480nm, 525nm, 375nm, 620nm
Emission filter:460nm, 535nm, 580nm, 600LP, 665LP


Key Benefits of Fluroescence Cell Analyzer

All in one design- Integrated Computer/Touch screen
Automatic Detection 5 Samples in one single test sequence.
Open platform with maximum 4 fluorescence Channel
User Friendly Cell Analysis Protocols
Unrivaled "Fixed focus" patent, no manual focusing.
High Stability and Actuary
Powerful and user-friendly Data Management
GMP and 21 CFR part 11 ready
FCS Express Software


Product feature

Up to 4 fluorescent channel and one bright field analysis in the same time



13 different fluorescent analysis combinations



User Friendly Cell Analysis Protocols

Trypan blue Protocols: Obtain cell count, viability and concentration estimations based on trypan blue staining using a disposable consumable.
AO/PI Viability Protocol: Run two fluorescence color assays in disposable consumable to determine the percentages of live, dead cells and concentration in the presents of debris and unwanted nonnucleated cell types including red blood cells.
Affinityof Antibody:This assay run as Green color assays in FITC binding antibody to determine the affinity of the biosimilar drug.
Surface Marker Assay:Quantify specific cell populations based on surface marker expression (CD45+ CD4+, CD8 + MSC, CD56+ NK cells, etc.)
Cell Cycle:Propidium iodide (PI) is a nuclear staining dye that is frequently applied in measuring cell cycle. The protocol determining cellular DNA content in cell cycle analysis
Cell Apoptosis:Cell Apoptosis assay is a type used for determining the apoptosis percentage of cells by Annexin V-FITC/7-ADD staining method.
GFP transfection:The green fluorescent protein (GFP) exhibits bright green fluorescence when exposed to light in the blue to ultraviolet range. This protocol can analyze counting and percentage of GFP.
Celling Killing:Run three fluorescence color assays in disposable consumable to determine the CAR T/NK-Mediated Cytotoxicity using Tracer and Viability Dyes

GMP and 21 CFR part 11 ready
Make a detailed record of any changes, edits, deletions, adjustments, etc. Electronic records cannot be deleted, including administrators. Electronic records include date, time, user name, machine serial number, and user's actions



FCS Express Software

The optional DeNovoTMFCS Express software makes graphs touchable and customizable fluorescence channel boost your experiment reach. Countstar Rigel S6 together with FCS Express is able to analyze for the cell apoptosis, cell cycle, transfection, affinity of antibody, CD marker and etc.

Specifications
Technical Specifications
Model:Countstar Rigel S6
Diameter range:3μm ~ 180μm
Concentration range:1×104 ~ 3×107/mL
Objective magnification:5x
Imaging element:1.4 megapixel, CCD camera
Excitation Light480nm, 525nm, 375nm, 620nm
Emission Filter460nm, 535nm, 580nm, 600LP, 665LP
USB1×USB 3.0 1×USB 2.0
Storage:500GB
Power supply:110–230 V/AC, 50/60Hz
Screen:10.4 inch touchscreen
Weight:13kg (28lb)
Size (W X D X H):Machine: 254×303×453mm Package size: 430×370×610mm
Operating temperature:10℃ ~ 40℃
Working humidity:20% ~ 80%

Applications
Dual-Fluorescence Viability

Acridine orange (AO) and Propidium iodide (PI) are nuclear nucleic acid binding dyes. The analysis excludes cell fragments, debris and artifacts particles as well as undersized events such as platelets, giving a highly accurate result. In conclusion, the Countstar system can be used for every step of the cell manufacturing process.




T/NK cell mediated cytotoxicity 
By labeling the target tumor cells with CFSE or transfect with GFP. Hoechst 33342 is used for stain all cells (both T cells and tumor cells), alternatively, target tumor cells can be stained with CFSE, PI is used for stain the dead cells (both T cells and tumor cells). This staining strategy allows for the discriminate of different cells.



Cell Apoptosis
The different phases of apoptosis are segmented into an early, middle and late stage. Specified indicators can document the single stages of apoptosis. The Countstar® Rigel S6 offers a visualized image-based solution and analyzes all of these steps with pre-loaded protocols in depth.

Cell Cycle
Countstar Rigel S6 enables users to get the result of a cell cycle quickly and accurately. Counstar Rigel S6 can analyze proportion of cell in different phase of the cell cycle.


Surface Maker Analysis
A lymphocyte subsets analysis is a typical experiment performed in cell related research fields and various diseases diagnosis. Countstar® Rigel S6 offers a faster and easier way to make immune cell typing more efficient. With visible cell images and powerful data analysis.


Affinity of antibody
Detect affinity of antibody in cell level is an important indicator of monoclonal antibody detection using immunofluorescence method.The Countstar® Rigel S6 offers a rapid, direct and reliable evaluating method for the affinity of antibody detection in antibody drug screening


GFP Transfection Efficiency
In cell and molecular biology, the GFP gene is frequently used as a reporter of expression. Currently, scientists are commonly using the fluorescent microscopes or flow cytometers to analyze the transfection efficiency of mammalian cells. But Flow cytometer requires a high-qualified and experienced operator. While Countstar Rigel S6 enables users to get the result of a transfection efficiency assay quickly and accurately.

评论

此博客中的热门博文

Countstar® Altair Advanced Cell Analyzer for Industry

Countstar® Altair Advanced Cell Analyzer for Industry Product Overview The Countstar ® Altair is designed based on the classic Trypan Blue exclusion principle, integrating the advanced “fix focus” optical imaging bench, the most advanced cell recognition technologies, and software algorithms. Enable to get the information of cell concentration, viability, aggregation rate, roundness, and diameter distribution by one run. To meet the cGMP regulation, Countstar® Atair software, equipped with a powerful data management function, offers a 4-level user access control feature, e-signatures, and log files that is in compliance with the FDA 21 CFR Part 11 regulations. Key Benefits of Countstar  Full Automated Cell Counter All in one design, integrated Computer/touch screen Automatic Detection 5 Samples in one single test sequence, 2.5 min /5 sample. Unrivaled "Fixed focus" patent, no manual focusing. Powerful and user-friendly Data Management Security User Login and ...

Countstar® BioLab Automated Cell Counter

Countstar® BioLab Automated Cell Counter Trypan Blue Cell Counting Aggregated Cell Analysis Easy Operation Product Overview Countstar BioLab is a cell counting and analyzing instrument developed on the basis of classic trypan blue staining. Integrating advanced optical imaging technology and intelligent image recognition technology. Countstar® BioLab is applicable to cells with diameter between 5-180μm and the density between 1×104-3×107/ml. Key Benefits Small Benchtop Instrument Simple and Easy Operation Fast testing time – less than 20s Maximum loaded 5 samples in one slide “Fixed Focus”– No manual focus adjustment needed Accurate and high reproducibility result – Intra-assay & Inter-assay CV <5% Maintenance and service free Product feature of  laboratory cell counter Easy and fast Within 20 seconds through three steps with one button Small Sample Volume Sample Volume: 20μL, Accuracy CV in measurements of a single counter is < ...