跳至主要内容

Countstar® Rigel S2 Fluorescence Cell Analyzer

Countstar® Rigel S2
Fluorescence Cell Analyzer

Precise cell analysis for:
  • PBMCs, whole blood, Car-T
  • Stem Cell Analysis
  • Splenocytes
  • Monocytes
  • And Other Primary Cells

Product Overview
The Countstar S2 System combines the two fluorescence channels plus a bright field digital microscope, an image cytometer, and a cell counter in a single bench-top instrument. This application-driven, compact, automated cell imaging system provides an all-in-one solution for cell counting, cell viability and Cell transfection efficiency through the use of preconfigured biological applications (BioApps). They are specifically optimized for analysis of primary cells from peripheral blood, including PBMC, CAR-T, NK cell and MSC, which commonly used in cell therapy.

Excitation light: 480nm, 525nm
Emission filter:535nm, 600LP


Key Benefits
  • Automatic detecting 5 samples for one time
  • GMP and 21 CFR Part 11 ready
  • Multi channel, multi functions
  • Simple, effortless operation
  • Maintenance and service free
  • All in one design- Touch screen user interface
  • User friendly and flexible software
Countstar Rigel S2 fluorescence analyzer feature
Smart
The BioApps of the Countstar Rigel S2 System simplify routine cell lab tasks while providing high quality scientific data.
Countstar S2 comes with three BioApps to simplify and automate the routine cell count, viability and cytotoxicity tasks.
Trypan blue BioApp: Obtain cell count, viability and concentration estimations based on trypan blue staining using a disposable consumable.
AO/PI Viability BioApp: Run two fluorescence color assays in disposable consumable to determine the percentages of live, dead cells and concentration in the presents of debris and unwanted nonnucleated cell types including red blood cells.
GFP transfection: The green fluorescent protein (GFP) exhibits bright green fluorescence when exposed to light in the blue to ultraviolet range. This protocol can analyze counting and percentage of GFP.


Three step process
The Countstar S2 System is designed to take you from sample to result in one go, simplifying your work and allowing for increased productivity and efficiency.


Reproducible and Accurate
Countstar S2 system can automatic detect 5 samples at one time, it will be more efficiency and affordable, with integrated patent “fixed focus”, the results would be more stable and reliable.


Touch Screen with Flexible Experiment Assay Management System
“App-like" interface. Allow to add multiple Experiment Assays for different operators

GMP ready
The Countstar S2 system is designed to meet the modern pharmaceutical requirements. The software complies with 21 CFR part 11. Key features include control of user access and data export, and secure audit trail. At the same time, we also supply IQ/OQ service and PQ support to help customer build a reliable system.

Specifications
Technical Specifications
Model:Countstar Rigel S2
Diameter range:3μm ~ 180μm
Concentration range:1×104 ~ 3×107/mL
Objective magnification:5x
Imaging element:1.4 megapixel ,CCD camera
Excitation Light480nm, 525nm
Emission Filter535nm, 600LP
USB1×USB 3.0 1×USB 2.0
Storage:500GB
Power supply:110–230 V/AC, 50/60Hz
Screen:10.4 inch touchscreen
Weight:13kg (28lb)
Size (W X D X H):Machine: 254×303×453mm Package size: 430×370×610mm
Operating temperature:10℃ ~ 40℃
Working humidity:20% ~ 80%


Applications
Monitoring the Quality of CAR-T Production during the whole Process
The immuno therapy, such as CAR-T involves the collection of peripheral blood mononuclear cells (PBMC) from the patient, then enrichment of the desired T cell subset followed by genetic modification to create engineered CAR-T cells. The CAR-T cells are expanded in large-scale and then infused back into the patient. With the Countstar S2 system it is possible to continuously monitor the viability and concentration every step of the entire process of manufacturing CAR-T cells under GMP.


Dual-Fluorescence Viability

Acridine orange (AO) and Propidium iodide (PI) are nuclear nucleic acid binding dyes. AO can penetrate to both dead and live cells and stains the nucleated cells to generate green fluorescence. PI can stain the dead nucleated cells with compromised membranes and generate red fluorescence. The analysis excludes cell fragments, debris and artifacts particles as well as undersized events such as platelets, giving a highly accurate result. In conclusion, the Countstar S2 system can be used for every step of the cell manufacturing process.


GFP Transfection Efficiency
In cell and molecular biology, the GFP gene is frequently used as a reporter of expression. Currently, scientists are commonly using the fluorescent microscopes or flow cytometers to analyze the transfection efficiency of mammalian cells. But Flow cytometer requires a high-qualified and experienced operator. While Countstar FL enables users to get the result of a transfection efficiency assay quickly and accurately. 


Trypan blue viability and concentration
Trypan blue viability and concentration assay also can be available on Countstar S2. Shown here, are the enlarged representative images of cell line. Since all of the cells were stained with trypan blue, we show the stained trypan blue image as well as the Countstar S2 counted image.

评论

此博客中的热门博文

Countstar® Altair Advanced Cell Analyzer for Industry

Countstar® Altair Advanced Cell Analyzer for Industry Product Overview The Countstar ® Altair is designed based on the classic Trypan Blue exclusion principle, integrating the advanced “fix focus” optical imaging bench, the most advanced cell recognition technologies, and software algorithms. Enable to get the information of cell concentration, viability, aggregation rate, roundness, and diameter distribution by one run. To meet the cGMP regulation, Countstar® Atair software, equipped with a powerful data management function, offers a 4-level user access control feature, e-signatures, and log files that is in compliance with the FDA 21 CFR Part 11 regulations. Key Benefits of Countstar  Full Automated Cell Counter All in one design, integrated Computer/touch screen Automatic Detection 5 Samples in one single test sequence, 2.5 min /5 sample. Unrivaled "Fixed focus" patent, no manual focusing. Powerful and user-friendly Data Management Security User Login and ...

Countstar® Rigel S6 Advanced Image Cytometer

Countstar® Rigel S6 Advanced Image Cytometer PBMC cell count and Primary Cell Count Cell Apoptosis Cell Cycle Surface Marker Analysis GFP Transfection Efficiency Optional FCS Express Software Product Overview Countstar ® Rigel S6 is an automated image-based cell analysis platform with full-spectrum fluorescence Microscope, FCS Express software, analysis and reporting of both data and image. Countstar® Rigel S6 equipped with 4 fluorescence channel, allow for 13 different fluorescent analysis combinations, support any dye of different wavelength. Excitation light: 480nm, 525nm, 375nm, 620nm Emission filter:460nm, 535nm, 580nm, 600LP, 665LP Key Benefits of  Fluroescence Cell Analyzer All in one design- Integrated Computer/Touch screen Automatic Detection 5 Samples in one single test sequence. Open platform with maximum 4 fluorescence Channel User Friendly Cell Analysis Protocols Unrivaled "Fixed focus" patent, no manual focusing. High Stability an...

Countstar® BioLab Automated Cell Counter

Countstar® BioLab Automated Cell Counter Trypan Blue Cell Counting Aggregated Cell Analysis Easy Operation Product Overview Countstar BioLab is a cell counting and analyzing instrument developed on the basis of classic trypan blue staining. Integrating advanced optical imaging technology and intelligent image recognition technology. Countstar® BioLab is applicable to cells with diameter between 5-180μm and the density between 1×104-3×107/ml. Key Benefits Small Benchtop Instrument Simple and Easy Operation Fast testing time – less than 20s Maximum loaded 5 samples in one slide “Fixed Focus”– No manual focus adjustment needed Accurate and high reproducibility result – Intra-assay & Inter-assay CV <5% Maintenance and service free Product feature of  laboratory cell counter Easy and fast Within 20 seconds through three steps with one button Small Sample Volume Sample Volume: 20μL, Accuracy CV in measurements of a single counter is < ...