跳至主要内容

Countstar® BioMarine Automatic Algae Counter

Countstar® BioMarine
Automatic Algae Counter

  • Algae Counting and Algae analysis 
  • Biomass of Algae
  • Screening Target Algae

Product Overview
Integrating advanced optical imaging technology and intelligent image recognition technology, Countstar® BioMarine Automated Counter is a professional automatic counter developed to accurately measure the concentrations of algae.

For both pure cultures of unicellular algae and mixed cultures of multi-algae samples, Countstar® BioMarine can provide accurate results with high repeatability and save your valuable time and energy.


Key Benefits
  • Easy operation
  • 20 sec. analysis time
  • Analyze different shapes of Algae
  • Wide Range Compatibility
  • Convenient screening

Product feature

Comprehensive algae information:


Countstar® BioMarine can automatically calculate the concentration, major axis length and minor axis length of algae and generate the algae growth curve, reflecting the growth of the algae.

Wide range compatibility:
Countstar® BioMarine is applicable to different shapes (i.e., spherical, elliptic, tubular, filamentous and cateniform) of unicellular and multi-cellular algae with axis length ranging from 2 µm to 180µm.

Convenient screening:
Countstar® BioMarine can screen target algae from complex samples for classification and counting by sizes or shapes.


Biomass Calculation:
To know the biomass of algae is basic for algae research. The traditional methods for analyzing biomass are Determination of the content of chlorophyll A – Accurate but complicated and time-consuming procedure. Spectrophotography – Need to use supersonic to destroy algae, not stable result and time-consuming.


Accurate and Excellent Reproducibility
Compared with the traditional hemocytometer, the result acquired by Countstar BioMarine shows a better linearity and a wider concentration range, and is thus more accurate.


Standard deviation shows Countstar BioMarine can accurately count selenastrum bibraianum cells; the error bar shows the average standard deviation.


Specifications
Technical Specifications
Model:IA 1000
Test Item:Concentration, Viability, Diameter, aggregation etc.
Sample Density:1x104 - 3x107/ml
Sample Diameter:2-180μm
Imaging element:5 Megapixel,CMOS camera
Objective magnification:5 X
Sample Volume:20μL
Test Time:<20s
Output:JPEG/PDF/EXCE

Countstar® BioMarine Automatic Algae Counter is your ideal product as algae counting methods.

评论

此博客中的热门博文

Countstar® Rigel S3 Fluorescence Cell Analyzer

Countstar® Rigel S3 Fluorescence Cell Analyzer CAR-T Cell cell mediated Cytotoxicity Studies Phenotypic Charaterization of CAR-T cells Viability and Concentration assay for : 1. Quality control of original blood samples 2. PBMC isolation efficiency tests 3. Cultured status of incubated T-lymphocytes 4. Process Monitoring of modified CAR-T cells 5. Final Product released control. Product Overview The Countstar S3 System combines the three fluorescence channels plus a bright field digital microscope, an image cytometer, and a cell counter in a single bench-top instrument. This application-driven, compact, automated cell imaging system provides an all-in-one solution for cell counting, cell viability and T/NK cell mediated cytotoxicity through the use of preconfigured biological applications (BioApps). They are designed to simplify routine cell lab tasks,which leaves you time to focus on the research! Excitation light: 375nm, 480nm, 525nm Emission filter:460nm, 535nm...

Countstar® Altair Advanced Cell Analyzer for Industry

Countstar® Altair Advanced Cell Analyzer for Industry Product Overview The Countstar ® Altair is designed based on the classic Trypan Blue exclusion principle, integrating the advanced “fix focus” optical imaging bench, the most advanced cell recognition technologies, and software algorithms. Enable to get the information of cell concentration, viability, aggregation rate, roundness, and diameter distribution by one run. To meet the cGMP regulation, Countstar® Atair software, equipped with a powerful data management function, offers a 4-level user access control feature, e-signatures, and log files that is in compliance with the FDA 21 CFR Part 11 regulations. Key Benefits of Countstar  Full Automated Cell Counter All in one design, integrated Computer/touch screen Automatic Detection 5 Samples in one single test sequence, 2.5 min /5 sample. Unrivaled "Fixed focus" patent, no manual focusing. Powerful and user-friendly Data Management Security User Login and ...

Stem Cell Therapy

Determination of viability, morphology and phenotype for stem cell therapy Mesenchymal stem cells are a subset of pluripotent stem cells which can be isolated from the mesoderm. With their self-replication renewal and multi-direction differentiation characteristics, they possess a high potential for various therapies in medicine. Mesenchymal stem cells have a unique immune phenotype and immune regulation ability. Therefore, mesenchymal stem cells are already widely used in stem cell transplantations, tissue engineering and organ transplantation. And Beyond these applications, they are used as an ideal tool in tissue engineering as seeder cells in a series of basic and clinical research experiments. stem cell analysis The Countstar FL can monitor the concentration, viability, apoptosis analysis and phenotype characteristics (and their changes) during the production and differentiation of these stem cells. The Countstar FL has also the advantage in obtaining additional morphologic...